dental electrosurgery,UltraFlex bendable electrodes
dental electrosurgery
DENTAL ULTRAFLEX BENDABLE ELECTRODES
electrode conversion and use chart

Electrodes also available in Rigid style.
Dental UltraFlex
Bendable Electrodes
Download PDF
INCISION: All below have fine .010” tungsten surgical wire for precise incision with minimum tissue alteration.
UF-F1
Adjustotip variable length, angled shaft (adjustable depth, especially effective posteriorly )
UF-F1 UltraFlex bendalble electrode
UF-F10
6mm wire, straight shaft, anterior specific
UF-F10 UltraFlex bendalble electrode
UF-F11
6mm wire, angled shaft
UF-F11 UltraFlex bendalble electrode
UF-F13
6mm wire, shaft reversed for posterior access
UF-F13 UltraFlex bendalble electrode

COAGULATION:
UF-C51
1,5 mm ball, angled shaft (for small area forced coagulation)
UF-C51 UltraFlex bendalble electrode
UF-C52
3mm ball, angled shaft (for medium area forced coagulation)
UF-C52 UltraFlex bendalble electrode
UF-C53
13mm .025” wire, straight shaft (for small spot forced coagulation, anterior specific)
UF-C54
13mm .025” wire, bent to 80 degrees @ 10mm, straight shaft
(for small spot forced coagulation)

UF-C15
.020” wire, right angle with straight shaft (for intraproximal spot forced coagulation, has thin insulation, especially recommended where metallic amalgams are present)
UF-C51 UltraFlex bendalble electrode
     

FULGURATION: NOTE: the UF-C52 is suitable for soft coagulation ( with the ME600 fulguration adaptor only ) of
enucleated cysts or creating a 1-1.5 mm coagulum over large areas for healing by second intent.
UF-SN61
angled, small point, stainless steel (for very small spot soft coagulation)
UF-SN61 UltraFlex bendalble electrode
UF-SN62
angled, medium spot, brass (for spot soft coagulation)
UF-SN62 UltraFlex bendalble electrode
R-SN62
rigid stainless steel version of above
UF-SN62 UltraFlex bendalble electrode
 

PERIODONTAL: NOTE: UF-L19, UF-L22, UF-L23, and UF-L29 are also useful for shallow periodontal treatment.
UF-L24
1,5mm X 15mm loop, 45 degree shaft, perpendicular loop
UF-SN61 UltraFlex bendalble electrode
UF-L25
1,5mm X 15mm loop, 45 degree shaft, parallel loop
UF-SN62 UltraFlex bendalble electrode
   

GINGIVAL TROUGHING: These electrodes are made of fine .010” surgical tungsten wire for minimal tissue alteration. They are also excellent for fine shaving and tissue tag removal. Those not specific to anterior access are suitable for both anterior and posterior, also, interproximal where access permits. NOTE: the UF-SN61 and R-SN62 stainless steel fulguration electrodes are also suitable for narrow, shallow troughing ( UF-SN61 is .5mm X 3mm and R-SN62 is 2mm X 6mm ). Deeper cuts with these electrodes may create some circatrix, however. The UF-SN61 fits easily interproximally. Due to the larger surface area, the UF-SN61 and R-SN61 will enhance concurrent hemostasis, when required, in comparison to the loops.
UF-L16
J shaped, 1mm X 2.3mm, right hook, angled shaft (anterior specific, V shaped trough)
UF-SN61 UltraFlex bendalble electrode
UF-L17
J shaped, 1mm X 2.3mm, left hook, angled shaft (anterior specific, V shaped trough)
UF-SN62 UltraFlex bendalble electrode
UF-L18
1.5mm X 5mm loop, straight shaft (anterior, U shaped trough)
UF-SN62 UltraFlex bendalble electrode
UF-L19
1.5mm X 7mm loop, 45 degree, straight shaft, loop perpendicular to shaft (U shaped trough)
UF-SN62 UltraFlex bendalble electrode

UF-L21
1mm X 6mm loop, 45 @ 4mm parallel to shaft, shaft bent @ 80 (posterior specific, U shaped trough)
UF-SN61 UltraFlex bendalble electrode
UF-L22
1.5mm X 8mm loop, 45 degree shaft, loop parallel to shaft (U shaped trough)
UF-SN62 UltraFlex bendalble electrode
UF-L23
1.5mm X 8mm loop, 45 degree shaft, loop perpendicular to shaft (U shaped trough)
UF-L29
1.5mm X 7mm loop, 45 degree, straight shaft, loop parallel to shaft (U shaped trough)
UF-SN62 UltraFlex bendalble electrode

UF-L38
2mm X 7mm loop, straight shaft (anterior specific, U shaped trough)
UF-SN61 UltraFlex bendalble electrode
UF-L39
2mm X 7mm loop, 45 degree, straight shaft, loop parallel to shaft (U shaped trough)
UF-SN62 UltraFlex bendalble electrode
UF-L41
2mm X 7mm loop, 90 degree shaft, loop parallel to shaft (U shaped trough)
UF-SN62 UltraFlex bendalble electrode
 

EXCISION: All below have fine .010” surgical tungsten wire for precise cuts with minimum tissue alteration.
UF-F12
14mm wire, straight shaft, wire bent 80 degrees @ 7mm (elliptical biopsy, incision, planing)
UF-F1 2 UltraFlex bendalble electrode
UF-L32
3,5mm round loop (planning, sculpting, or biopsy)
UF-L32 UltraFlex bendalble electrode
UF-L33
5mm round loop (planning, sculpting, especially sulcus, or biopsy)
UF-L33 UltraFlex bendalble electrode
UF-L34
10mm round loop (planning, sculpting, or biopsy, also effective for frenectomy)
UF-L34 UltraFlex bendalble electrode

UF-L45
13mm round loop (planning, large biopsy, also effective for frenectomy)
UF-F1 2 UltraFlex bendalble electrode
UF-L35
3mm X 7mm oval loop, straight (pontic recess sculpting, concave sculpting, biopsy)
UF-L32 UltraFlex bendalble electrode
UF-L36
4mm X 10mm oval loop, straight (pontic recess sculpting, concave sculpting, biopsy)
UF-L33 UltraFlex bendalble electrode
UF-L37
3mm X 7mm oval loop, angled as above (also effective for palatal stripping)
UF-L34 UltraFlex bendalble electrode

UF-L42
4mm X 7mm oval loop, angled as above (also effective for palatal stripping)
UF-L42 UltraFlex bendalble electrode
UF-L31
5mm X 5mm square loop, straight (biopsy, interseptal papilla, donor graft harvesting)
UF-L31 UltraFlex bendalble electrode
UF-L26
4mm x 4mm triangle loop, straight (ridge trim, tuberosity reduction, shallow angle concave sculpting, donor graft harvesting)
UF-L33 UltraFlex bendalble electrode
 

RESTORATIVE DENTISTRY
UF-F1, UF-11 incision, crown eleongation, composite exposure, subgingival carie exposure
UF-L22 pupotomy, remove tissue tags, gigivectomy
UF-L34 hyperplastic tissue planning, frenectomy
UF-L35 gingival contouring, palatal stripping, crown lengthening
UF-SN62 spot fulguration, coagulation of pin point exposure
UF-C52 large area coagulation, desensitizing hypersensitive dentin, bleaching
UF-F13 per UF-F11, except specific to posterior access
UF-C15 interproximal coagulation
ORAL SURGERY
UF-F1, UF-F11 incision, operculectomy, uninterrupted tooth exposure, cyst enucleation
UF-L35 palatal stripping
UF-L45 large excisional biopsy, hyperplastic tissue reduction (planing)
UF-C51 1.5mm ball, coagulation
R-C54, R-C55 .025” ss wire, for incision with very pronounced concurrent hemostasis
UF-SN61 pin point fulguration, dessication of lesions in situ
UF-SN62 spot fulguration, effective near nutrient foramen on exposed bone
UF-C15 interproximal coagulation
PROSTHODONTICS
UF-F1, UF-F11 incision
UF-F13 incision (posterior specific: reverse angle bend)
UF-F16, UF-F17 shallow troughing (right and left hooks, V groove)
UF-L19, UF-L29 troughing, fine planing gingiplasty (parallel and perpendicular, close, U groove)
UF-L32, UF-L33, UF-L34 create sulcus, planning, gingiplasty, biopsy (3,5mm, 5mm, 10mm loops)
UF-L35, UF-L36 pontic and sulcus sculpture, planning, gingiplasty (straight shaft oval loop)
UF-L37, UF-L42 as above, also palatal stripping (angled shaft)
UF-L26 gingiplasty, planning, donor graft harvesting (triangle loop)
UF-L31 gingiplasty, planning, donor graft harvesting (square loop)
UF-L22, UF-L23 troughing, planning, gingiplasty, tissue tags (parallel and perpendicular)
UF-C51, UF-C52 coagulation balls for forced coagulation
UF-C15, UF-C55 spot coagulation (UF-C15 is interproximal specific)
UF-SN61 fine fulguration, also suitable for fine, shallow V troughing
UF-SN62 fulguration
R-SN62 as above, but stainless steel suitable for fine, shallow V troughing
PERIODONTAL
UF-F1, UF-F11 incision, gingivectomy, frenectomy
UF-L24, UF-L25 gingival curettage, gingivectomy, tissue tags
UF-L22, UF-L23 shallow gingival curettage
UF-L26, UF-L31 graft donor tissue harvesting
UF-C51 coagulation
UF-SN62 spot fulguration
ENDODONTICS
UF-F1, UF-F11 incision
UF-L22 pulpotomy
UF-L35, UF-L34 hyperplastic tissue reduction
UF-C51 hemostasis and sterilization of endodontic canals, intracoronal bleaching
UF-C52 large area coagulation, accelerate bleaching procedures
UF-SN62 spot fulguration, pin point exposure coagulation
Care & Cleaning of Electrodes After Use
1. Do not scrub electrodes with a brush or harsh abrasive.
2. To remove blood or tissue prior to autoclaving, place the electrodes in hydrogen peroxide or in an ultrasonic cleaner for 1 minute. If carbon deposits cannot be wiped off, use a fine sandpaper disc to expose the metal.
3. Place the electrodes in an autoclave bag before placing them in an autoclave bag. Steam autoclave at 250ºF (121ºC) for 20 minutes at 15 psi.
4. An aluminum paste may be used to remove oxide.
Macan Engineering & Manufacturing Company
1564 N. Damen Avenue, Chicago, IL. 60622 - U.S.A
Phone: (773) 772 - 2000 or Toll free: (866) 622- 2611