PERFORMANCE
& PREDICTABILITY
- Bleeding
control
- Planning
of soft tissue
- Easier
access to all areas of the mouth
- Reduce
chair time
- Bacterial
free incisions
- Improved
restoration quality
|
|
Bipolar
Forceps
Why spend $6,000 on a
bi-polar machine?
|
|
|
|
|
Introducing
the RadioSurge
|
|
|
|
|
RadioSurge
vs. Laser
|
 |
|
|
| The Radiosurge
(MC-6A) is a high precision dental electrosurgery
unit especially effective for delicate and intricate tissue
management in prosthodontics, but versatile and affordable
for all dental health care specialties. The Radiosurge
MC-6A offers cicatrix free CUT mode, incision and excision
with pronounced concurrent homeostasis in BLEND mode,
and pin-point accurate coagulation in COAG mode. This
unit has been UL tested to full operating room standards;
the isolated output instrument is safe for concurrent
use with monitoring equipment such as EKG monitors, apnea
monitors, and pulse oximeters. The isolated output allows
safe and effective bipolar coagulation, which is effective
in wet or bloody fields even on exposed bone as well as
soft tissue and small vessels. Low voltage output for
virtually "spark-free" incisions that help to
assure patient comfort under all anesthesia conditions
and significantly reduces any risk of tissue damage or
recession. The isolated output means that the unit absolutely
will not work without the dispersive plate. The unit comes
with our unique "Flexi-plate" which resides
on the chair eliminating the need for attention with each
case. Simple attachment allows ready portability between
rooms and supple design insures patient comfort. The unit
works through normal street clothing and comes with a
set of 6 "Ultra=flex" dental electrodes, a 5
year warranty and Owner's Manual. IEC 60601-1-2 EMC compliance
make this instrument as friendly as possible around other
equipment. |
Cut
Mode -
This fully rectified, filtered waveform is the safest and most
predictable waveform for oral electrosurgery procedures. When
utilizing the cut mode in healthy tissue, there will be no shrinkage.
It produces a continuous flow of RF energy that provides a micro-smooth
cut with minimal hemostatsis. Indications would include cosmetic
elongation of clinical crowns, anterior gingival troughing before
crown & bridge impressions, biopsies, frenectomies, reflection
of full thickness flaps and any procedures that closely proximate
bone or dental implants.
Cut + Coag Mode - Clinically, this fully rectified waveform
results in a blend of 50% cutting and 50% coagulation. It would
be the waveform of choice for posterior gingival troughing before
crown & bridge gaining access to subgingival caries, removing
opercula, removing opercula, removing pericoronal tissue, pulpotomies,
gingivectomies and gingivoplasty procedures.
Coag Mode - This partially rectified waveform of intermittent
RF energy flow is highly effective in producing hemostasis in
gingival an mucosal tissues and sealing off bleeders up to two
millimeters in diameter without ligation. Indications include
soft tissue coagulation after surgical intervention or bleeding
= a pulpotomy. This waveform may also be used for sterilization
of endodontic canals, bleaching discolorized teeth and desensitzation
of cervical tooth margins.
Fulguration Mode - This mode produces a spark that travels
through the air gap between the electrode tip and the surface
of the tissue. It is the only monopolar electrosurgical waveform
that can coagulate bleeding coming from the bone. It is also
excellent to diagnose and coagulate possible pin-point exposures.
|
|
RADIOSURGE
MC6A ELECTROSURGERY UNIT TECHNICAL SPECIFICATIONS
|
| IEC
CLASSIFICATION class 2 medical, high frequency
surgical, non-ionizing radiation device |
| CONFIGURATION
monopolar, isolated output, type BF ports |
| OPERATING
MODES |
CUT |
CW
.5% ripple, max 50watts into 100ohms +10%-5%, crest
factor 1.4 |
| OUTPUT
VOLTAGE 500V p-p (.5kVp p-p), open load, SURGE
mode |
| SOURCE
IMPEDANCE 500ohms, nominal |
| OPERATING
FREQUENCY 3.0mHz +/-5%, nominal |
| POWER
CONTROL manual analog, continuously variable |
| OPERATIONAL
DUTY CYCLE 10 seconds ON, 20 seconds OFF (not
electronically enforced) |
| TEMPERATURE
RANGE -20C to +85C storage, OC to +40C operating,
<80% RH non condensing |
| COOLING
convection |
| SPALSH
RATING IPO |
| ACTUATION
single foot pedal (isolated low voltage circuit,
IP20 splash resistant rust proof plastic pedal)
|
| DISPERSIVE
MONITOR N/A |
| ACTIVE
INDICATION LED light, tone (defeatible) |
| POWER
REQUIRMENTS |
120V
60Hz, +/-10%, 240watts maximum consumption |
| |
230V
50HZ, +/-10%, 240VA maximum consumption |
| |
NOTE:
field selection of operating voltage requires a
skilled technician |
| SIZE
AND WEIGHT |
8.5"w,
3.5"h, 5.75"d, not including controls
and jacks 5.5pounds (9 pound shipping) |
| |
21,6cm
w; 8.89cm h; 14.6cm d; not including controls and
jacks 2.5kg (4.1kg shipping) |
| WARRANTY
5 years (exclusive of accessories) |
|
Notified
Body: Canadian Standards Association |
|
Standard:
CAN/CS C22.2 No. 601.1-M90 |
|
Mark:
C/US mark registration number 222103 |
|
Tested
to:
|
IEC
60601-1-1 Medical Safety |
|
IEC
60601-1-2 Electromagnetic Compatibility |
|
IEC
60601-1-2 High Frequency Surgical Particular Standards |
Construction
Printed circuit boards. Filtered, full and partial wave
solid state rectification with vacum tube oscillator.
Aircraft-strength aluminum chassis and cover.
ACCESSORIES
The Radio
Surge comes complete with autoclaveable handpiece and cord,
six Ultra Flex Bendable Electrodes (UF-L22, UF-C51, UF-L34,
UF-L35, UF-F1, UF-SN62), thermoplastic coated ground plate,
ground cord and a 14 page operating manual. Special length cables
are available for custom installations.
| SIZE |
11.5"
X 6.5" X 2.75" (205.5 cu ") |
| WEIGHT |
6
lbs. |
Electrodes

|
Dispersive
Plate and Cord

|
Handpiece and Cord

|
Forceps
|
|
|
|
|
Macan Engineering & Manufacturing Company
1564 N. Damen Avenue, Chicago, IL. 60622 - U.S.A
Phone: (773) 772 - 2000 or Toll free: (866) 622- 2611
Fax: (773) 772 - 2003
|
|
|
|
 |
 |
|
|